Product Model■
Mic-R-Sys405/ 532/ 785
Specifications ■
Microscope
GMM-580
|
Microscope model
|
Coarse and fine Coaxial focus
|
Z-axis focusing system
|
Minimum graduation: 2μm,
|
Limit stopper device
|
210mm*140mm
|
X/Y Mobile stages size
|
50mm*75mm
|
Stage moving range
|
5 Megapixel Imaging System ISH500 (Optional)
|
Camera
|
5X-100X (Optional)
|
Microscope objective
|
Camera
CMOS, colorized, progressive scanning
|
Chip
|
1/2.5 inch
|
Chip size
|
5 million
|
Effective pixels
|
2.2μm*2.2μm
|
Pixels size
|
2592*1944
|
Max Resolution (H×V)
|
5fps(2592 × 1944 full resolution); 21fps(1280*960);
|
Frame rate
|
25fps (1024 × 768); 38fps (640 × 480)
|
24 bit
|
Color depth
|
54 dB
|
Noise of amplitude
|
0-60
|
Operating temperature(°C)
|
High speed USB2.0
|
Data interface
|
Standard C-mount
|
Lens mount
|
Laser
785±0.3
|
532±0.5
|
405±0.5
|
Wavelength (nm)
|
Single
|
Single
|
Single
|
Mode
|
<2
|
<0.5
|
-
|
Spectral line width (cm-1)
|
>350, >450
|
1-1000
|
1-500
|
Output power (mW)
|
<2%
|
<1%,<3%,<5%
|
<2%
|
Power stability (pk-pk, 4 hours)
|
100um@0.22NA
|
100um@0.22NA
|
100um@0.22NA
|
Parameter of fiber
|
<0.5%,<1%
|
<0.5%
|
-
|
Noise of amplitude (rms)
|
CW
|
CW
|
CW
|
Operating mode
|
<5
|
<10
|
<5
|
Warm-up time (minutes)
|
-10-40
|
15-25
|
10-35
|
Operating temperature (℃)
|
10000
|
10000
|
10000
|
Expected lifetime (hours)
|
1 year
|
1 year
|
1 year
|
Warranty
|
Spectrometer
405-500nm
|
532-700nm
|
785-1100nm
|
Wavelength range
|
(405nm excitation)
|
(532nm excitation)
|
(785nm excitation)
|
18-24cm-1
|
8-12cm-1
|
5-8cm-1
|
Optical resolution
|
(405nm excitation)
|
(532nm excitation)
|
(785nm excitation)
|
2048 pixels
|
Pixels
|
14um*14um
|
Pixels size
|
149*109*50
|
Dimensions (mm)
|
1000
|
Weight (g)
|
1000:01:00
|
Signal-to-noise ratio
|
17ms-10s
|
Integration time
|
450mA@5VDC
|
Power consumption
|
Full scans into memory every 4 milliseconds with USB 2.0
|
Data transfer speed
|
Full scans into memory every 18 milliseconds with USB 1.1
|
5 inputs and 5 outputs (opto-isolator inputs/outputs)
|
Inputs/outputs
|
One 12 analog input one 12 analog output
|
Analog channels
|
Raman Probe
405
|
532
|
785
|
Excitation wavelength (nm)
|
7.5
|
Probe focus length(mm)
|
Probe material is 2A12 after Blackening; Stainless steel detector tip
|
Probe main material
|
Two single fiber (100um excitation fiber, 200um optical fiber for collecting light); N.A.=0.22, PVC/metal sheath; 1m Length
|
Fiber configuration
|
Software
Spectral Analysis / Raman Analysis 2.0
|
Optical spectrum analysis
|
Imaging
|
Camera imaging
|
Windows XP/Win7 (32bits or 64 bits)
|
Operating system
|
لطفا جهت اطلاع از قیمت تماس بگیرید.
|